IESNA:LM-63-2002 [TEST]ITL59674 "[TESTLAB]INDEPENDENT TESTING LABORATORIES, INC." [ISSUEDATE]01/11/08 [MANUFAC]PHILIPS LIGHTING [LUMCAT]BARE LAMP ABSOLUTE PHOTOMETRY "[LAMPCAT]CDM20/830/PAR30/M/SP, CUSTOMER SAMPLE DATE CODE K7 LAMP 3" "[LAMP]ONE PRE-PRODUCTION 20-WATT PAR-30 SPOT CERAMIC METAL HALIDE," [MORE]VERTICAL BASE-UP POSITION. "[BALLAST]VOSSLOH-SCHWABE, INC. M2012CK-7EUN (ITL SAMPLE A10) CUSTOMER" [MORE]STATES BALLAST ADJUSTED TO OPERATE LAMP AT 22 WATTS. [OTHER]TOTAL INPUT WATTS = 26.8 AT 120.0 VOLTS [OTHER]TEST DISTANCE = 25.25 FEET [_NOTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT [MORE]VOLTAGE (120VAC) TO THE BALLAST. TILT=NONE 1 1191 1 75 1 1 1 -0.291667 -0.291667 0.020833 1.000 1 26.8 0 .5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 10.5 11 11.5 12 12.5 13 13.5 14 14.5 15 15.5 16 16.5 17 17.5 18 18.5 19 19.5 20 21 22 23 24 25 26 27 28 29 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0 33703 33529 32248 30094 27310 24242 21097 18116 15324 12916 10767 8948 7406 6132 5032 4151 3434 2860 2398 2026 1725 1484 1286 1126 986 874 774 691 618 556 500 452 409 377 340 313 290 272 256 243 232 215 203 188 179 170 161 154 150 155 155 154 155 139 100 73 57 45 36 28 22 17 14 12 12 10 5 4 4 3 2 1 0 0 0